LLH150MU Hydraulic Separator

Home PageLLH150MU Hydraulic Separator

Rhella LLH150MU hydraulic separator with dirt magnet

Hydraulic separator

LLH150MU

Hydraulic separator with dirt magnet

The Rhella LLH150MU combines four functions in one 304 stainless steel vessel: it separates the primary (boiler or chiller) circuit from the secondary (system) circuits so each pump runs without disturbing the other, and it removes air, dirt and ferrous particles from the water. Sized for 21 gpm at 4 ft/s, with G1¾″ union with 1½″ press, sweat or FNPT tail connections.

21 gpmFlow at 4 ft/s G1¾″Connections 150 psiMax. pressure 210 °FMax. temperature

4-in-1 performance

1

Hydraulic separation

A low-velocity zone between the primary and secondary connections decouples the boiler and system pumps.

2

Air removal

The stainless mesh web merges micro-bubbles so they rise to the automatic air vent.

3

Dirt removal

Slow water lets dirt settle to the bottom, where it is flushed out through the drain.

4

Magnetite removal

A 12,000 gauss neodymium rod in a dry well holds ferrous particles; pull the rod to release them.

Dimensions

LLH150MU dimensional drawing

Dimensions, mm / in

ABCDEF
mm203534112260162133
in8.021.04.410.26.45.2

A Width across the connection faces · B Overall height of the vessel · C Top of vessel to upper connections · D Between upper and lower connections · E Lower connections to bottom of vessel · F Vessel outside diameter. Heights exclude the air vent, drain valve and fittings.

Connections

#PortSize and type
1Primary and secondary connections (4)G1¾″ union with 1½″ press, sweat or FNPT tail
2Air vent port½″ GM
3Drain½″ GM
4Dirt magnet portdry well with removable rod
5Gauge port¼″ FNPT
6Fill / makeup water port, on the side (expansion tank or system fill)½″ FNPT

Technical data

Flow at 4 ft/s21 gpm (4.7 m³/h)
Pressure drop at 4 ft/s0.25 ft primary / 0.25 ft secondary
Max. operating pressure150 psi (10 bar)
Operating temperature32–210 °F (0–99 °C)
FluidsWater, or water with up to 50 % glycol
VesselØ 133 × 2 mm, 304 stainless steel
Coalescing elementStainless steel mesh web (expanded metal, 7 mm diamond openings) dividing the primary and secondary halves
Dirt magnetØ16 mm neodymium rod, M50 grade, 12,000 gauss, in a dry well
Weight11.4 lb (5.2 kg)
Water volumeapprox. 1.7 US gal
Warranty2 years

Performance

Pressure drop

LLH150MU pressure drop chart

Primary side: supply to return connection. Secondary side: return to supply connection. Computed with 3D CFD of the vessel and its internals; pressure drop rises with the square of the flow.

Separation performance

LLH150MU separation performance chart

Unwanted mixing: share of the heat that should reach the system but returns to the boiler instead. 3D CFD with buoyancy, 20 °F design ΔT, primary at 21 gpm. Mixing at balanced flow 2.7 %; onset (≥ 5 %): none; breakdown (≥ 15 %): none.

How to read the separation chart (click to open)

A hydraulic separator joins two loops: the primary loop, with the boiler (or chiller) and its pump, and the secondary loop, with the heating system and its pumps. Hot water from the boiler should go out to the system, and the cooler water coming back from the system should go back to the boiler. Some of the hot water can instead turn around inside the separator and go straight back to the boiler. This is called unwanted mixing, and the chart shows how much of it happens.

  • Across the bottom is how much water the system pumps draw, in gpm. The boiler pump stays at 21 gpm, the LLH150MU’s rated flow.
  • Up the side is unwanted mixing: the share of the boiler’s heat that returns to the boiler instead of reaching the system. 0 % is perfect; 10 % means 10 of every 100 units of heat come straight back.
  • The dotted line marks the point where the system draws exactly as much water as the boiler pump delivers. Mixing is usually highest near this line and falls off on either side.

The coloured zones

  • White, below 5 %: the separator works as intended. The effect is too small to notice.
  • Yellow, 5 to 15 %: some hot water short-circuits back to the boiler. The boiler gets slightly warmer return water and the system slightly cooler supply water. A condensing boiler loses a little efficiency.
  • Red, above 15 %: separation is breaking down. A large share of the heat circulates back to the boiler: a condensing boiler condenses less and runs less efficiently, the boiler may switch on and off more often, and the system may not reach the supply temperature it was designed for.

What this means for the LLH150MU: The curve stays in the white zone at every system flow. Its highest point is 2.7 %, when the system draws the same 21 gpm as the boiler pump delivers. In practice the boiler and the heating system work independently of each other across the whole range.

The curve comes from 3D computer flow simulations (CFD) at a 20 °F temperature difference between supply and return. A real installation can differ somewhat with piping layout and temperatures.

Sizing and installation

Select the separator for the larger of the primary and secondary flows. The listed flow is the flow at 4 ft/s in the connections, a reference point and not a limit; higher flows are possible with higher pressure drop.

Install vertically with the vent at the top, the primary circuit on one side and the secondary on the other: supply connections at the upper pair, returns at the lower pair. Keep straight pipe of at least 5 pipe diameters before each inlet, and provide isolation valves so the magnet and drain can be serviced.

Maintenance

Open the drain periodically to blow down settled dirt. To release the collected magnetite, pull the rod out of its dry well: the magnetite drops to the bottom and is flushed out at the next blowdown. The automatic air vent needs no routine service.

Typical specification

Furnish and install a Rhella LLH150MU hydraulic separator, or approved equal, selected for 21 gpm (4 ft/s connection velocity). The separator shall combine hydraulic separation of the primary and secondary circuits with air, dirt and ferrous-particle removal in one vessel. The vessel shall be 304 stainless steel with G1¾″ union with 1½″ press, sweat or FNPT tail primary and secondary connections, internal stainless steel mesh web (expanded metal, 7 mm diamond openings) dividing the primary and secondary halves, an automatic air vent at the top, a drain at the bottom, a fill port, and a removable 12,000 gauss neodymium rod magnet in an external dry well. Maximum working pressure 150 psi; working temperature 32–210 °F; suitable for water and glycol solutions up to 50 %.

Flow and performance simulator